Network Service Configuration

Before changing the network service to NVMe-TCP, please remember to remove iSCSI network portals while initiators are still connected.

We only allow changing the network service on ETH2 between iSCSI and NVMe-TCP.

$ purenetwork eth setattr --servicelist nvme-tcp ct0.eth2 ct1.eth2
Name  	Enabled  Type  	Subnet  Address  	Mask         	Gateway 	MTU   MAC            	Speed   	Services  Subinterfaces
ct0.eth2  True 	physical  -   	172.16.9.48  255.255.255.128  172.16.9.1  1500  6e:05:91:b6:80:e5  16.00 Gb/s  nvme-tcp  -
ct1.eth2  True 	physical  -   	172.16.9.62  255.255.255.128  172.16.9.1  1500  22:eb:6f:e1:06:99  16.00 Gb/s  nvme-tcp  -

Array Host and Volume Configuration

Array host and volume configuration follows the same procedure as the FlashArray. Please reference Connecting an NVMe-oF Initiator to a Volume.

Array Scale Limit

Description Limit
Max # of hosts 300
Max # of volumes 800