1. Using
purehw list to get the health status of all the underlying infrastructure: Controller VMs, Managed Disks, and Network interfaces.
purehw list
Output Example:
purecli@cbsavspv2> purehw list
Name Status Identify Slot Index Speed Temperature Voltage Details
CT0 ok - - 0 - - - -
CT0.BAY0 ok - - 0 - - - -
CT0.ETH0 ok - 0 0 30.00 Gb/s - - -
CT0.ETH1 ok - 1 1 30.00 Gb/s - - -
CT0.ETH2 ok - 2 2 30.00 Gb/s - - -
CT0.ETH3 ok - 3 3 1.00 Gb/s - - -
CT0.ETH4 ok - 4 4 30.00 Gb/s - - -
CT0.ETH5 ok - 5 5 30.00 Gb/s - - -
CT1 ok - - 1 - - - -
CT1.BAY0 ok - - 0 - - - -
CT1.ETH0 ok - 0 0 30.00 Gb/s - - -
CT1.ETH1 ok - 1 1 30.00 Gb/s - - -
CT1.ETH2 ok - 2 2 30.00 Gb/s - - -
CT1.ETH3 ok - 3 3 1.00 Gb/s - - -
CT1.ETH4 ok - 4 4 30.00 Gb/s - - -
CT1.ETH5 ok - 5 5 30.00 Gb/s - - -
SH0 ok - - 0 - - - -
SH0.BAY0 ok - - 0 - - - -
SH0.BAY1 ok - - 1 - - - -
SH0.BAY2 ok - - 2 - - - -
SH0.BAY3 ok - - 3 - - - -
SH0.BAY4 ok - - 4 - - - -
SH0.BAY5 ok - - 5 - - - -
SH0.BAY6 ok - - 6 - - - -
SH0.BAY7 ok - - 7 - - - -
SH0.BAY8 ok - - 8 - - - -
SH0.BAY9 ok - - 9 - - - -
SH0.BAY10 ok - - 10 - - - -
SH0.BAY11 ok - - 11 - - - -
SH0.BAY12 ok - - 12 - - - -
SH0.BAY13 ok - - 13 - - - -
SH0.BAY14 ok - - 14 - - - -
SH0.BAY15 ok - - 15 - - - -
2. Using
puredrive list to get the health status of the drives (managed disks) only.
puredrive list
Output Example:
pureuser@am-662-test-cbs> puredrive list
Name Type Status Capacity Details
CT0.BAY0 cache healthy 1.17T -
SH0.BAY0 virtual NVRAM healthy 2.00G -
SH0.BAY1 virtual NVRAM healthy 2.00G -
SH0.BAY2 virtual SSD healthy 1.98T -
SH0.BAY3 virtual SSD healthy 1.98T -
SH0.BAY4 virtual SSD healthy 1.98T -
SH0.BAY5 virtual SSD healthy 1.98T -
SH0.BAY6 virtual SSD healthy 1.98T -
SH0.BAY7 virtual SSD healthy 1.98T -
SH0.BAY8 virtual SSD healthy 1.98T -
SH0.BAY9 virtual SSD healthy 1.98T -
SH0.BAY10 virtual SSD healthy 1.98T -
SH0.BAY11 virtual SSD healthy 1.98T -
SH0.BAY12 virtual SSD healthy 1.98T -
SH0.BAY13 virtual SSD healthy 1.98T -
SH0.BAY14 virtual SSD healthy 1.98T -